The rooftop refrigeration unit range covers 1–8 m³ boxes in integrated and split configurations, with 12V, 24V, 48V, 60V and 72V DC power and an optional 220V backup.




Models and specifications
| Model | Refrigerant | Temperature | Box volume | Cooling capacity | Mounting | Power | Defrost | Backup |
|---|---|---|---|---|---|---|---|---|
| GP1000 | R134a | −5°C to 10°C chiller | 1 – 3 m³ | 900 W at 0°C | Integrated rooftop | 12V / 24V / 48V / 60V / 72V | Optional | Optional 220V backup |
| GP2000 | R404a | −18°C to 10°C freezer | 1 – 3 m³ | 1400 W at 0°C / 900 W at −15°C | Integrated rooftop | 12V / 24V / 48V / 60V / 72V | Optional | Optional 220V backup |
| GP1000E | R134a | −5°C to 10°C chiller | 1 – 3 m³ | 900 W at 0°C | Split rooftop | 12V / 24V / 48V / 60V / 72V | Optional | Optional 220V backup |
| GP2000E | R404a | −18°C to 10°C freezer | 1 – 3 m³ | 1400 W at 0°C / 900 W at −15°C | Split rooftop | 12V / 24V / 48V / 60V / 72V | Optional | Optional 220V backup |
| TK500 | R404a | −18°C to 10°C freezer | 5 – 8 m³ | 3800 W at 0°C / 2100 W at −15°C | Integrated rooftop | 72V | Standard | Optional 220V backup |
| TK500F | R404a | −18°C to 10°C freezer | 5 – 8 m³ | 3800 W at 0°C / 2100 W at −15°C | Split rooftop | 72V | Standard | Optional 220V backup |
Selection noteCooling capacity, box volume, ambient temperature and door-opening frequency are assessed together. The final unit is confirmed against the configuration sheet and vehicle commissioning.
Need a refrigeration unit matched to your box?
Send the box volume, target temperature, vehicle power and duty cycle and we will propose a unit.